Model | SK-Z300C |
Type | High frequency cleaning type |
Power Input | DC24V±10% |
Current Consumption | 80mA |
Output Voltage | AC Approx. 2,500V |
Ion Balance*¹ | ±15V or less |
Connection Tube | Φ6 |
Operating air pressure | 0.05MPa~0.6MPa |
Airflow adjustment function | Have |
Air flow | Approx. 40L/min when adjusting the minimum flow rate; |
Approx. 400L/min when adjusting the maximum flow rate. | |
Ozone generating capacity | 0.05ppm or less (Input air pressure: 0.05MPa, measuring distance 300mm) |
Operating environment | 0~40°C / 65%RH or less (no condensation) |
Alarm output (ALARM) | NPN type optical relay output, connector 3-pin: normally open, connector 4-pin: normally closed, Maximum current: 100mA, Applied voltage: DC30V or less |
Cleaning check output (C.C) | NPN type optical relay output, connector pin 2, normally open, maximum current: 100mA, applied voltage: maximum 30V DC |
Discharge stop input (HV-OFF) | Discharge stop: 0V and short circuit, Discharge allowable: open circuit (Residual voltage: 0.5V or less) |
Dimensions | 86.5×18×50mm (W×H×D), no protrusion |
Material | Case: PBT, outer rubber: stainless steel, discharge pin: tungsten |
Weight | 78g (body only) |