Note: *1. The response time is delayed by about 20% for different frequencies set under the anti-interference function menu. Model LA2-WS300 Type Cable type Output type NPN/PNP Detecting distance 30~300mm Minimum spot diameter Variable spot
Approx. Ф2±0.2 mm at 90 mm
Approx. Ф5±0.5 mm at 200 mm
Approx. Ф7±0.8 mm at 300 mm Response time 200us / 1ms / 10ms / 100 ms / 500 ms switching type Light source White LED Reduction of mutual
interference frequency Setting of different frequencies, max. 2 units*¹ Timer OFF / turn-on delay / turn-off delay / single time Power voltage 12-30VDC±10% Current consumption Less than 65 mA at 24V (without load)
Less than 120 mA at 12V (without load) Control output*² NPN open collector/PNP open collector Switching type
30 V or less, 50 mA or less
Residual voltage 2 V or less
N.O./N.C. switching type External input*² Tuning/stopping Switching type Protection circuits Power reverse connection protection, power surge protection, output overcurrent protection,
output surge protection, output reverse connection protection Enclosure protection class IP65/IP67 (IEC60529) Ambient light Incandescent:below 10000Ix Sunlight:below 20000lx Ambient temperature -20 to +50°C (no freezing) Relative humidity 35 to 85% RH (no condensation) Shock resistance 1,000 m/s² 6 times in each direction X, Y, Z Vibration resistance 10 to 55 Hz Dual amplitude 1.5 mm 2 hours in each direction X, Y, Z Cable length (mm) 2000 (Highly flexible drag chain type) Material Zinc alloy Weight Approx. 170 g
*2. OUT2 multiplexes the white line with the external input, and when the white line is set to output, there is no external input.