Main model
DH-004
DH-M005
DH-M008
DH-M012
DH-M018
DH-M030
DH-U008
DH-U012
DH-U018
DH-U030
Type
Shielded
Non-shielded
Detecting distance
1.2mm±10%
2mm±10%
4mm±10%
8mm±10%
15mm±10%
4mm±10%
8mm±10%
16mm±10%
30mm±10%
Setting distance
0~0.84mm
0~1.6mm
0~3.2mm
0~6.4mm
0~12mm
0~3.2mm
0~6.4mm
0~12.8mm
0~24mm
Standard target
5×5×1(mm)
8×8×1(mm)
12×12×1(mm)
24×24×1(mm)
45×45×1(mm)
12×12×1(mm)
24×24×1(mm)
48×48×1(mm)
90×90×1(mm)
Response frequency
2KHz
1.5KHz
1KHz
0.5KHz
0.25KHz
1KHz
0.8KHz
0.4KHz
0.1KHz
Hysteresis
1%~10% of detecting distance
1%~15% of detecting distance
1%~15% of detecting distance
Repeat precision
Less than 3% of detecting distance
Less than 5% of detecting distance
Less than 5% of detecting distance
Power voltage
12~24VDC
10~30VDC
10~30VDC
Current consumption
<10mA
<10mA
<15mA
<22mA
<10mA
<15mA
<22mA
Output
-
NPN output
NPN open collector transistor
Load current: <100mA
Residual voltage: <2V (Load current 100mA and cable 2 m)
<200mA
2.5V or less(Load current 200mA and cable 2 m)
NPN output
NPN open collector transistor
Load current: <100mA
Residual voltage: <2V (Load current 100mA and cable 2 m)
<200mA
2.5V or less(Load current 200mA and cable 2 m)
Indicator
Yellow indicator (Lights up when output is ON)
Protection circuit
Reverse polarity protection, Output short-circuit protection, Surge absorber
Ambient temperature
Using:-25℃~+70℃; Storage:-25℃~+70℃
Relative humidity
Using:35~95%; Storage:35~95%
Withstand voltage
500VAC, 50/60Hz 1min between the whole charging part and the enclosure
1000VAC, 50/60Hz 1min between the whole charging part and the enclosure
1000VAC,50/60Hz 1min between the whole charging part and the enclosure
Insulation resistance
>20MΩ (DC500V) between the whole charging part and the enclosure
>50MΩ (DC500V) between the whole charging part and the enclosure
>50MΩ (DC500V) between the whole charging part and the enclosure
Vibration resistance
10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance
500m/s² (Approx. 50G), 3 times in each of the X, Y, and Z directions
Protective structure
IEC IP67
Connection method
Standard wire length 2m
Material
Enclosure: Nickel-plated brass, Front end: PBT, Back end: PC
Weight
-
Approx. 50g
Approx. 95g
Approx. 115g
Approx. 190g
Approx. 50g
Approx. 95g
Approx. 115g
Approx. 190g
Main model | DH-EM008 | DH-EM012 | DH-EM018 | DH-EM030 | DH-EU008 | DH-EU012 | DH-EU018 | DH-EU030 |
Type | Shielded | Non-shielded | ||||||
Detecting distance | 2mm±10% | 4mm±10% | 8mm±10% | 15mm±10% | 4mm±10% | 8mm±10% | 16mm±10% | 30mm±10% |
Setting distance | 0~1.6mm | 0~3.2mm | 0~6.4mm | 0~12mm | 0~3.2mm | 0~6.4mm | 0~12.8mm | 0~24mm |
Standard target | 8×8×1(mm) | 12×12×1(mm) | 24×24×1(mm) | 45×45×1(mm) | 12×12×1(mm) | 24×24×1(mm) | 48×48×1(mm) | 90×90×1(mm) |
Response frequency | 1.5KHz | 1KHz | 0.5KHz | 0.25KHz | 1KHz | 0.8KHz | 0.4KHz | 0.1KHz |
Hysteresis | 1%~15% of detecting distance | |||||||
Repeat precision | Less than 5% of detection distance | |||||||
Power voltage | 10~30VDC | |||||||
Current consumption | <10mA | <15mA | <22mA | <10mA | <15mA | <22mA | ||
Output |
NPN output NPN open collector transistor Load current: <100mA Residual voltage: <2V (Load current 100mA and cable 2 m) <200mA 2.5V or less(Load current 200mA and cable 2 m) |
|||||||
Indicator | Yellow indicator (Lights up when output is ON) | |||||||
Protection circuit | Reverse polarity protection, Output short-circuit protection, Surge absorber | |||||||
Ambient temperature | Using:-25℃~+70℃; Storage:-25℃~+70℃ | |||||||
Relative humidity | Using:35~95%; Storage:35~95% | |||||||
Withstand voltage | 1000V AC, 50/60Hz 1min between the whole charging part and the enclosure | |||||||
Insulation resistance | >50MΩ (DC500V) between the whole charging part and the enclosure | |||||||
Vibration resistance | 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |||||||
Shock resistance | 500m/s² (Approx. 50G), 3 times in each of the X, Y, and Z directions | |||||||
Protective structure | IEC IP67 | |||||||
Connection method |
Connector rM8-3Pin |
Connector M12-4Pin |
Connector M8-3Pin |
Connector M12-4Pin | ||||
Material | Enclosure: Nickel-plated brass (Except SN08 housing is stainless steel), Front end: PBT, Back end: PC | |||||||
Weight | Approx. 20g | Approx. 30g | Approx. 60g | Approx. 130g | Approx. 20g | Approx. 30g | Approx. 60g | Approx. 130g |
Main model | DH-CM008 | DH-CM012 | DH-CM018 | DH-CM030 | DH-CU008 | DH-CU012 | DH-CU018 | DH-CU030 |
Type | Shielded | Non-shielded | ||||||
Detecting distance | 2mm±10% | 4mm±10% | 8mm±10% | 15mm±10% | 4mm±10% | 8mm±10% | 16mm±10% | 30mm±10% |
Setting distance | 0~1.2mm | 0~1.6m | 0~4mm | 0~8mm | 0~1.6mm | 0~3.2mm | 0~6.4mm | 0~12mm |
Standard target | 8×8×1(mm) | 12×12×1(mm) | 18×18×1(mm) | 30×30×1(mm) | 8×8×1(mm) | 12×12×1(mm) | 24×24×1(mm) | 45×45×1(mm) |
Response frequency | 2KHz | 1.5KHz | 1KHz | 0.5KHz | 1KHz | 0.8KHz | 0.4KHz | 0.1KHz |
Hysteresis | 1%~15% of detecting distance | |||||||
Repeat precision | Less than 5% of detection distance | |||||||
Power voltage | 10~30VDC | |||||||
Output | NO/NC | |||||||
Load current | <100mA | |||||||
Residual voltage | <5V | |||||||
Indicator | Yellow indicator (Lights up when output is ON) | |||||||
Protection circuit | Reverse polarity protection, Output short-circuit protection, Surge absorber | |||||||
Ambient temperature | Using:-25℃~+70℃; Storage:-25℃~+70℃ | |||||||
Relative humidity | Using:35~95%; Storage:35~95% | |||||||
Withstand voltage | 1000V AC, 50/60Hz 1min between the whole charging part and the enclosure | |||||||
Insulation resistance | >50MΩ (DC500V) between the whole charging part and the enclosure | |||||||
Vibration resistance | 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |||||||
Shock resistance | 500m/s² (Approx. 50G), 3 times in each of the X, Y, and Z directions | |||||||
Protective structure | IEC IP67 | |||||||
Connection method |
Connector M8-3Pin |
Connector M12-4Pin |
Connector M8-3Pin |
Connector M12-4Pin | ||||
Material | Enclosure: Nickel-plated brass, Front end: PBT, Back end: PC | |||||||
Weight | Approx. 20g | Approx. 30g | Approx. 60g | Approx. 130g | Approx. 20g | Approx. 30g | Approx. 60g | Approx. 130g |
Main model | DH2-M008 | DH2-M012 | DH2-M018 | DH2-M030 | DH2-U008 | DH2-U012 | DH2-U018 | DH2-U030 |
Type | Shielded | Non-shielded | ||||||
Detecting distance | 2mm±10% | 4mm±10% | 8mm±10% | 15mm±10% | 4mm±10% | 8mm±10% | 16mm±10% | 30mm±10% |
Setting distance | 0~1.2mm | 0~1.6m | 0~4mm | 0~8mm | 0~1.6mm | 0~3.2mm | 0~6.4mm | 0~12mm |
Standard target | 8×8×1(mm) | 12×12×1(mm) | 18×18×1(mm) | 30×30×1(mm) | 8×8×1(mm) | 12×12×1(mm) | 24×24×1(mm) | 45×45×1(mm) |
Response frequency | 2KHz | 1.5KHz | 1KHz | 0.5KHz | 1KHz | 0.8KHz | 0.4KHz | 0.1KHz |
Hysteresis | 1%~15% of detecting distance | |||||||
Repeat precision | Less than 5% of detecting distance | |||||||
Power voltage | 10~30VDC | |||||||
Output | NO/NC | |||||||
Load current | <100mA | |||||||
Residual voltage | <5V | |||||||
Indicator | Yellow indicator (Lights up when output is ON) | |||||||
Protection circuit | Reverse polarity protection, Output short-circuit protection, Surge absorber | |||||||
Ambient temperature | Using:-25℃~+70℃; Storage:-25℃~+70℃ | |||||||
Relative humidity | Using:35~95%; Storage:35~95% | |||||||
Withstand voltage | 1000V AC、50/60Hz 1min between the whole charging part and the enclosure | |||||||
Insulation resistance | >50MΩ (DC500V) between the whole charging part and the enclosure | |||||||
Vibration resistance | 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |||||||
Shock resistance | 500m/s² (Approx. 50G), 3 times in each of the X, Y, and Z directions | |||||||
Protective structure | IEC IP67 | |||||||
Connection method | Standard wire length 2m | |||||||
Material | Housing: Nickel-plated brass, Front end: PBT, Back end: PC | |||||||
Weight | Approx. 20g | Approx. 30g | Approx. 60g | Approx. 130g | Approx. 20g | Approx. 30g | Approx. 60g | Approx. 130g |
Main model | DH2-EM008 | DH2-EM012 | DH2-EM018 | DH2-EM030 | DH2-EU008 | DH2-EU012 | DH2-EU018 | DH2-EU030 |
Type | Shielded | Non-shielded | ||||||
Detecting distance | 2mm±10% | 4mm±10% | 8mm±10% | 15mm±10% | 4mm±10% | 8mm±10% | 16mm±10% | 30mm±10% |
Setting distance | 0~1.2mm | 0~1.6m | 0~4mm | 0~8mm | 0~1.6mm | 0~3.2mm | 0~6.4mm | 0~12mm |
Standard target | 8×8×1(mm) | 12×12×1(mm) | 18×18×1(mm) | 30×30×1(mm) | 8×8×1(mm) | 12×12×1(mm) | 24×24×1(mm) | 45×45×1(mm) |
Response frequency | 2KHz | 1.5KHz | 1KHz | 0.5KHz | 1KHz | 0.8KHz | 0.4KHz | 0.1KHz |
Hysteresis | 1%~15% of detecting distance | |||||||
Repeat precision | Less than 5% of detecting distance | |||||||
Power voltage | 10~30VDC | |||||||
Output | NO/NC | |||||||
Load current | <100mA | |||||||
Residual voltage | <5V | |||||||
Indicator | Yellow indicator (Lights up when output is ON) | |||||||
Protection circuit | Reverse polarity protection, Output short-circuit protection, Surge absorber | |||||||
Ambient temperature | Using:-25℃~+70℃; Storage:-25℃~+70℃ | |||||||
Relative humidity | Using:35~95%; Storage:35~95% | |||||||
Withstand voltage | 1000V AC, 50/60Hz 1min between the whole charging part and the enclosure | |||||||
Insulation resistance | >50MΩ (DC500V) between the whole charging part and the enclosure | |||||||
Vibration resistance | 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |||||||
Shock resistance | 500m/s² (Approx. 50G), 3 times in each of the X, Y, and Z directions | |||||||
Protective structure | IEC IP67 | |||||||
Connection method |
Connector M8-3Pin |
Connector M12-4Pin |
Connector M8-3Pin |
Connector M12-4Pin | ||||
Material | Enclosure: Nickel-plated brass, Front end: PBT, Back end: PC | |||||||
Weight | Approx. 20g | Approx. 30g | Approx. 60g | Approx. 130g | Approx. 20g | Approx. 30g | Approx. 60g | Approx. 130g |
Main model | DH2-CM008 | DH2-CM012 | DH2-CM018 | DH2-CM030 | DH2-CU008 | DH2-CU012 | DH2-CU018 | DH2-CU030 |
Type | Shielded | Non-shielded | ||||||
Detecting distance | 2mm±10% | 4mm±10% | 8mm±10% | 15mm±10% | 4mm±10% | 8mm±10% | 16mm±10% | 30mm±10% |
Setting distance | 0~1.2mm | 0~1.6m | 0~4mm | 0~8mm | 0~1.6mm | 0~3.2mm | 0~6.4mm | 0~12mm |
Standard target | 8×8×1(mm) | 12×12×1(mm) | 18×18×1(mm) | 30×30×1(mm) | 8×8×1(mm) | 12×12×1(mm) | 24×24×1(mm) | 45×45×1(mm) |
Response frequency | 2KHz | 1.5KHz | 1KHz | 0.5KHz | 1KHz | 0.8KHz | 0.4KHz | 0.1KHz |
Hysteresis | 1%~15% of detecting distance | |||||||
Repeat precision | Less than 5% of detecting distance | |||||||
Power voltage | 10~30VDC | |||||||
Output | NO/NC | |||||||
Load current | <100mA | |||||||
Residual voltage | <5V | |||||||
Indicator | Yellow indicator (Lights up when output is ON) | |||||||
Protection circuit | Reverse polarity protection, Output short-circuit protection, Surge absorber | |||||||
Ambient temperature | Using:-25℃~+70℃; Storage:-25℃~+70℃ | |||||||
Relative humidity | Using:35~95%; Storage:35~95% | |||||||
Withstand voltage | 1000V AC, 50/60Hz 1min between the whole charging part and the enclosure | |||||||
Insulation resistance | >50MΩ (DC500V) between the whole charging part and the enclosure | |||||||
Vibration resistance | 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |||||||
Shock resistance | 500m/s² (Approx. 50G), 3 times in each of the X, Y, and Z directions | |||||||
Protective structure | IEC IP67 | |||||||
Connection method |
Connector M8-3Pin |
Connector M12-4Pin |
Connector M8-3Pin |
Connector M12-4Pin | ||||
Cable length | 0.3m | |||||||
Material | Housing: Nickel-plated brass, Front end: PBT, Back end: PC | |||||||
Weight | Approx. 20g | Approx. 30g | Approx. 60g | Approx. 130g | Approx. 20g | Approx. 30g | Approx. 60g | Approx. 130g |