Home > Products > Laser Sensors > Ultra-long Distance TOF Type > Digital Type > LA-H Series > Specs

Laser Sensors

Digital Type- LA-H Series

Sensor head

Model LA-H45 LA-H45L LA-H130 LA-H130L LA-H450 LA-H450L LA-H1000 LA-H1000L
Detecting distance (mm)
(Amplifier display value)
20 to 45
(250 to 0)
55 to 130
(750 to 0)
160 to 450
(290 to 0)
200 to 1000
(800 to 0)
Amplifier display range 259 to -34 768 to -98 295 to -50 810 to -175
Light source Type Red laser (639nm)
Laser type Class 2 Class 1 Class 2 Class 1 Class 2 Class 1 Class 2 Class 1
Output 400uW 250uW 400uW 250uW 600uW 250uW 600uW 250uW
Standard detection offset 0.5mm 1mm 3mm 20mm
( detecting distance is 200-800mm )
30mm
( detecting distance is 800-1000mm )
Protection class IP67
Ambient temperature -10 to +50 °C (no freezing)
Relative humidity 35 to 85% RH ( no condensation)
Ambient luminosity Incandescent: 7500lx  Daylight: 10000lx
Material Housing: PBT  Indicator cover: PC  Lens cap: glass  Cable: PVC
Wire length 160mm
Weight Approx. 60g Approx. 80g Approx. 130g
Mounting bracket (optional) OW-LAH001 OW-LAH002 OW-LAH003

Controller

NPN output

Model LA-21 LA-22
Main module / Expansion module Main module Expansion module
Output type NPN
Mounting type DIN rail mounting
Sensor head compatibility Available
Display Minimum display unit LA-H450: 1mm, LA-1000: 5mm
Display range LA-H450: -50mm to 295mm, LA-1000: -175mm to 810mm
Display rate Approx. 10 times/sec.
Analog voltage output ±5V, 1 to 5V, 0 to 5V output impedance 100Ω -
Analog current output 4 to 20 mA maximum load resistance 350Ω
Control input Channel switching input NPN: ON when connected to 0V, OFF when connected to 24V;
PNP: ON when connected to 24V, OFF when connected to 0V;
Zero drift input
Transmit stop input
Timer input
Reset input
Control output*¹ Judgment output Open collector, 50mA max (NPN/PNP; normally open/closed, switchable)
Alarm output Open collector, 50mA max (NPN/PNP; normally closed, non-switchable)
Power supply Power voltage*¹ 10 to 30 VDC including ripple (P-P) 10% Class 2 or lower Power supply through the main unit
Power consumption (without load) 1950 mW or less (at 30 V, 65 mA max.) 1800 mW or less (at 30 V, 60 mA max.)
Ambient temperature -10 to + 50 °C ( no freezing )
Ambient humidity 35 to 85% RH ( no condensation)
Vibration resistance 10 to 55 Hz, 1.5 mm dual amplitude, 2 hours each for X, Y, and Z axes
Material Housing: Polycarbonate Key: Polyacetal Cable: PVC
Cable length 2m
Weight (including accessories) Approx. 150g Approx. 140g

*1 The following limitations apply depending on the number of units to be connected to the expansion unit.
When connecting 2 to 8 units including the main unit
- Power supply voltage: 20 to 30 VDC
- Control output current: 20 mA max.



PNP output

Model LA-21P LA-22P
Main module / Expansion module Main module Expansion module
Output type PNP
Mounting type DIN rail mounting
Sensor head compatibility Available
Display Minimum display unit LA-H450: 1mm, LA-1000: 5mm
Display range LA-H450: -50mm to 295mm, LA-1000: -175mm to 810mm
Display rate Approx. 10 times/sec.
Analog voltage output ±5V, 1 to 5V, 0 to 5V output impedance 100Ω -
Analog current output 4 to 20 mA maximum load resistance 350Ω
Control input Channel switching input NPN: ON when connected to 0V, OFF when connected to 24V;
PNP: ON when connected to 24V, OFF when connected to 0V;
Zero drift input
Transmit stop input
Timer input
Reset input
Control output*¹ Judgment output Open collector, 50mA max (NPN/PNP; normally open/closed, switchable)
Alarm output Open collector, 50mA max (NPN/PNP; normally closed, non-switchable)
Power supply Power voltage*¹ 10 to 30 VDC including ripple (P-P) 10% Class 2 or lower Power supply through the main unit
Power consumption (without load) 1950 mW or less (at 30 V, 65 mA max.) 1800 mW or less (at 30 V, 60 mA max.)
Ambient temperature -10 to + 50 °C ( no freezing )
Ambient humidity 35 to 85% RH ( no condensation)
Vibration resistance 10 to 55 Hz, 1.5 mm dual amplitude, 2 hours each for X, Y, and Z axes
Material Housing: Polycarbonate Key: Polyacetal Cable: PVC
Cable length 2m
Weight (including accessories) Approx. 150g Approx. 140g
*1 The following limitations apply depending on the number of units to be connected to the expansion unit.
When connecting 2 to 8 units including the main unit
- Power supply voltage: 20 to 30 VDC
- Control output current: 20 mA max.